GE MASTR II
Repeater &Station Combination Numbers

Reading Combination Numbers (digits left to right)

1
2
3
4
5
6
7
8 & 9
Mechanical
Package
Duty
Cycle
Power
Output
Channel
Spacing
Control
Number
of Freq.
Options
Frequency
Range
D
30 - inch
Desk Mate
I
120/240 VAC
Intermittent
4
8 - 16
Watts
4
20 KHz
K
Local /
Remote DC
A
1-Freq. Tx
1-Freq. Rx
D
Duplex
12
25 - 30
MHz
13
30 - 36
MHz
S
44 - inch
Desk Mate
C
120/240 VAC
Continuous
5
16 - 38
Watts
5
25 KHz
R
DC Remote
B
2-Freq. Tx
1-Freq. Rx
G
CG & UHS
23
36 - 42
MHz
33
42 - 50
MHz
P
Pole Mount
Station
6
38 - 68
Watts
6
30 KHz
U
Remote /
Repeat DC
C
2-Freq. Tx
2-Freq. Rx
L
CG
Duplex
44
66 - 77
MHz
45
77 - 88
MHz
V
Floor Mount
Station
7
66 - 128
Watts
D
1-Freq. Tx
2-Freq. Rx
N
Noise Blanker
56
138-150.8
MHz
66
150.8 - 174
MHz
E
3-Freq. Tx
3-Freq. Rx
P
UHX RX
77
406 - 420
MHz
88
450 - 470
MHz
F
4-Freq. Tx
4-Freq. Rx
S
Standard
89
470 - 494 MHz
91
494 - 512 MHz
U
Channel
Guard (CG)
W
CG &
Noise Blanker