Some Common Coax Data
 
Freq. in MHz / Loss db/100 ft.
Z
         
Coax type
100
200
400
700
900
Ohms
Vf
Cap. per Ft. O.D. Shield Notes
Belden 9913
1.30
1.80
2.70
3.60
4.20
50
.84 24.6 pF 0.405 100% braid shield over foil shield
Belden 9914
1.60
2.40
3.50
5.00
5.70
50
.82 24.8 pF 0.403 100% braid shield over foil shield
Belden 8214
(RG-8/U)
1.80
2.70
4.20
5.80
6.70
50
.78 26.0 pF 0.405 97%  
Belden 8238
(RG-11/U)
2.00
2.90
4.20
5.80
6.80
75
.66 20.5 pF 0.405 97%  
Belden 8267
(RG-213/U)
1.90
2.70
4.10
6.50
7.60
50
.66 30.8 pF 0.405 97%  
Belden 8268
(RG-214/U)
1.90
2.70
4.10
6.50
7.60
50
.66 30.8 pF 0.425 97% double silver shield
Belden 8242
(RG-9/U)
2.10
3.00
4.80
6.50
7.60
51
.66 30.0 pF 0.42 98% silver inner double shield
Belden 9258
(RG-8/X)
3.70
5.40
8.00
11.10
12.80
50
.80 25.3 pF 0.242 95%  
Belden 84142
(RG-142)
3.90
5.60
8.20
11.00
12.50
50
.695 29.2 pF 0.195 98% brown FEP jacket - double silver shield
Belden 9273
(RG-223/U)
4.10
6.00
8.80
12.00
13.80
50
.66 30.8 pF 0.212 95% double silver shield
Belden 8240
(RG-58/U)
4.50
6.80
10.00
14.00
16.00
51.5
.66 29.9 pF 0.195 95%  
Belden 8259
(RG-58A/U)
4.90
7.30
11.50
17.00
20.00
50
.66 30.8 pF 0.193 95%  
Belden 9259
(RG-59/U)
3.00
4.50
6.60
8.90
10.1
75
.78 17.3 pF 0.242 95%  
Belden 8241
(RG-59/U)
3.40
4.90
7.00
9.70
11.1
75
.66 20.5 pF 0.242 95%  
Belden 8216
(RG-174/U)
8.40
12.50
19.00
27.00
31.00
50
.66 30.8 pF 0.101 90%  
Belden 9228
(RG-62A/U)
2.70
3.80
5.30
7.30
8.20
93
.84 13.5 pF 0.242 95%  
Coax type
100
200
400
700
900
Ohms
Vf
Cap. per Ft. O.D. Shield Notes



Coax Cable Type Signal Loss per 100 feet
* RG-174 RG-58 RG-8X RG-213 RG-6 RG-11 RF-9914 RF-9913
1MHz 1.9dB 0.4dB 0.5dB 0.2dB 0.2dB 0.2dB 0.3dB 0.2dB
10MHz 3.3dB 1.4dB 1.0dB 0.6dB 0.6dB 0.4dB 0.5dB 0.4dB
50MHz 6.6dB 3.3dB 2.5dB 1.6dB 1.4dB 1.0dB 1.1dB 0.9dB
100MHz 8.9dB 4.9dB 3.6dB 2.2dB 2.0dB 1.6dB 1.5dB 1.4dB
200MHz 11.9dB 7.3dB 5.4dB 3.3dB 2.8dB 2.3dB 2.0dB 1.8dB
400MHz 17.3 B 11.2dB 7.9dB 4.8dB 4.3dB 3.5dB 2.9dB 2.6dB
700MHz 26.0dB 16.9dB 11.0dB 6.6dB 5.6dB 4.7dB 3.8dB 3.6dB
900MHz 27.9 B 20.1dB 12.6dB 7.7dB 6.0dB 5.4dB 4.9dB 4.2dB
1GHz 32.0dB 21.5dB 13.5dB 8.3dB 6.1dB 5.6dB 5.3dB 4.5dB
Z 50 50 50 50 75 75 50 50


Andrew LDF4-50A 1/2" Heliax
Attenuation and Average Power
Frequency
MHz
Attenuation
dB/100 ft
Attenuation
dB/100 m
Average
Power, KW
0.5 0.045 0.149 40.0
1 0.064 0.211 35.8
1.5 0.079 0.259 29.2
2 0.091 0.299 25.3
10 0.205 0.672 11.3
20 0.291 0.954 7.93
30 0.357 1.17 6.46
50 0.463 1.52 4.98
88 0.619 2.03 3.73
100 0.661 2.17 3.49
108 0.688 2.26 3.36
150 0.815 2.67 2.83
174 0.880 2.89 2.62
200 0.946 3.10 2.44
300 1.17 3.83 1.97
400 1.36 4.46 1.70
450 1.45 4.75 1.59
500 1.53 5.02 1.51
512 1.55 5.08 1.49
600 1.69 5.53 1.37
700 1.83 6.01 1.26
800 1.97 6.46 1.17
824 2.00 6.56 1.15
894 2.09 6.85 1.10
960 2.17 7.12 1.06
1000 2.22 7.28 1.04
1250 2.51 8.23 0.921
1500 2.77 9.09 0.833
1700 2.97 9.74 0.777
1800 3.07 10.1 0.753
2000 3.25 10.7 0.710
2100 3.34 11.0 0.691
2200 3.43 11.2 0.673
2300 3.52 11.5 0.657
3000 4.09 13.4 0.565
3400 4.39 14.4 0.526
4000 4.82 15.8 0.479
5000 5.49 18.0 0.421
6000 6.11 20.1 0.378
8000 7.26 23.8 0.318
8800 7.69 25.2 0.300
Andrew LDF5-50A 7/8" Heliax
Attenuation and Average Power
Frequency
MHz
Attenuation
dB/100 ft
Attenuation
dB/100 m
Average
Power, KW
0.5 0.025 0.081 91.0
1 0.035 0.115 78.6
1.5 0.043 0.141 64.1
2 0.050 0.163 55.5
10 0.112 0.366 24.6
20 0.159 0.521 17.3
30 0.195 0.641 14.1
50 0.254 0.833 10.8
88 0.340 1.12 8.08
100 0.364 1.19 7.56
108 0.378 1.24 7.26
150 0.449 1.47 6.12
174 0.486 1.59 5.66
200 0.523 1.72 5.26
300 0.649 2.13 4.24
400 0.758 2.49 3.63
450 0.808 2.65 3.41
500 0.855 2.81 3.22
512 0.866 2.84 3.17
600 0.945 3.10 2.91
700 1.03 3.37 2.67
800 1.11 3.63 2.48
824 1.13 3.69 2.44
894 1.18 3.87 2.34
960 1.23 4.02 2.24
1000 1.25 4.12 2.19
1250 1.42 4.67 1.93
1500 1.58 5.18 1.74
1700 1.70 5.56 1.62
1800 1.75 5.75 1.57
2000 1.86 6.11 1.48
2100 1.92 6.29 1.44
2200 1.97 6.46 1.40
2300 2.02 6.63 1.36
3000 2.37 7.76 1.16
3400 2.55 8.37 1.08
4000 2.81 9.23 0.978
5000 3.23 10.6 0.853

 

 

   
Andrew FSJ1-50A 1/4" Superflex Heliax
Attenuation and Average Power
Frequency
MHz
Attenuation
dB/100 ft
Attenuation
dB/100 m
Average
Power, KW
0.5 0.124 0.407 6.40
1 0.176 0.577 6.40
1.5 0.215 0.707 6.40
2 0.249 0.816 6.40
10 0.559 1.83 3.97
20 0.792 2.60 2.80
30 0.973 3.19 2.28
50 1.26 4.14 1.76
88 1.68 5.52 1.32
100 1.79 5.89 1.23
108 1.87 6.13 1.19
150 2.21 7.25 1.00
174 2.39 7.82 0.929
200 2.56 8.41 0.865
300 3.16 10.4 0.701
400 3.67 12.1 0.603
450 3.91 12.8 0.567
500 4.13 13.5 0.537
512 4.18 13.7 0.530
600 4.54 14.9 0.488
700 4.93 16.2 0.450
800 5.29 17.4 0.419
824 5.38 17.6 0.412
894 5.61 18.4 0.395
960 5.83 19.1 0.380
1000 5.96 19.6 0.372
1250 6.72 22.0 0.330
1500 7.41 24.3 0.299
1700 7.94 26.0 0.279
1800 8.19 26.9 0.271
2000 8.67 28.5 0.256
2100 8.91 29.2 0.249
2200 9.14 30.0 0.243
2300 9.37 30.7 0.237
3000 10.9 35.6 0.204
3400 11.6 38.2 0.191
4000 12.8 41.8 0.174
5000 14.5 47.5 0.153
6000 16.1 52.7 0.138
8000 19.0 62.4 0.117
10000 21.7 71.2 0.102
12000 24.2 79.4 0.092
14000 26.6 87.2 0.084
16000 28.8 94.6 0.077
18000 31.0 101.7 0.072
19000 32.1 105.2 0.069
20000 33.1 108.6 0.067
20400 33.5 110.0 0.066
 


50 Ohm  COAXIAL CABLES
from ADVANCED DIGITAL CABLE

 
Description
UL / NEC
Rating
Advanced
Digital
Cable
Part No.
Conductor
AWG/Type
In mm
Insulation
Type
In mm
Shield
Construction
coverage
Jacket
Type
In mm
Nominal
Impedance
Ohms
Nominal
Cap
pF/ft
pF/m
Nominal
Velocity
of

Prop.%

Nominal
Attenuation
Mhz dB/100 ft
RG 58/U

AWM 1354

CM

4-8058

20 (Solid)

Bare Copper

.032 .81

PE

 

.116 2.95

Tinned Copper Braid

95%

PVC

.195 4.95

52

28.5

93.4

66

10
50
100
200
400
700
1000

 

1.10
2.50
3.80
5.60
8.40
11.70
14.50

RG 58/U

AWM 1354

CM

4-8058 BC

20 (Solid)

Bare Copper

.032 .81

PE

.116 2.95

Bare Copper Braid

95%

PVC

.195 4.95

52

28.5

93.4

66

10
50
100
200
400
700
1000

 

1.10
2.50
3.80
5.60
8.40
11.70
14.50

RG 58 A/U

AWM 1354

CM

4-8058A

20 (Stranded)
19/33
Tinned Copper
.036 .89

PE

.116 2.95

Tinned

Copper Braid

95%

PVC

.195 4.95

50

30.5

100

66

10
50
100
200
400
700
1000

 

1.50
3.10
4.90
7.30
11.50
17.00
21.50

RG 58 C/U

MIL TYPE

AWM 1354

8058C

20 (Stranded) 19/33
Tinned Copper
.036 .89

PE

.116 2.95

Tinned

Copper Braid

95%

NC PVC

.195 4.95

50

30.5

100

66

10
50
100
200
400
700
1000

 

1.50
3.10
4.90
7.30
11.50
17.00
21.50

RG 58 A/U

AWM 1354

CM

4-8258A

20 (Stranded) 19/32
Tinned Copper
.037 .94

FPE

.114 2.90

Tinned

Copper Braid

95%

PVC

.195 4.95

52

25.0

83.0

78

10
50
100
200
400
700
1000

 

1.20
2.50
3.80
5.60
8.40
11.70
14.50

RG 58
THINNET

AWM 1354

CM

4-8079

20 (Stranded) 19/32
Tinned Copper
.037 .94

FPE

.101 2.57

Foil +
Tinned
Copper Braid

93%

PVC

.183 4.67

50

25.4

83.3

82

10
50
100
200
400
700
1000

 

1.30
2.90
4.20
6.10
8.90
12.10
14.80

RG 58/U

AWM 1354

8158

20 (Solid) Bare Copper

.032 .81

PE

.116 2.95

Bare Copper Braid

80%

PVC

.195 4.95

52

28.5

93.4

66

10
50
100
200
400
700
1000

 

1.40
3.10
4.50
6.80
10.00
14.00
17.00



Glossary of Abbreviations

Amp
AC
AL
AWG
AWM
BC
C
CATV
CCTV
CCS
CL2
CL3
CM
CMA
CSA
Cu
dB
DC
ETP
f
F
FEP
FPE
FPL
FRPE
FT4
G
GHz
Hz
I
K
KHz
L
m
M
MHz
n
NCPVC
NEC
nF
NFPA
OFC
p
PE
pF
PLTC
PP
PTFE
PU
PVC
RG
SC
TC
TPE
TPR
u
uF
UL
XLPE

Ampere – the standard unit of measure for current.
Alternating Current
Aluminum
American Wire Gage
Appliance Wiring Material
Bare Copper
Capacitance or Celsius
Community Antenna Television – Article 820 of the National Electrical Code
Closed-circuit television
Copper Clad Steel
Class 2 circuits – Article 725 of the National Electrical Code
Class 3 circuits – Article 725 of the National Electrical Code
Communications cables – Article 800 of the National Electrical Code
Circular mil area
Canadian Standards Association
Copper
Decibel
Direct Current
Electrolytic tough pitch – the standard electrical grade of copper wire
Frequency
Farad – the standard unit measure for capacitance
Fluorinated ethylene-propylene – a DuPont plastic compound in the Teflon family
Foamed polyethylene
Power-limited fire alarm circuits – Article 760 of the National Electrical Code
Flame retardant polyethylene
A cable marking used to indicate that a cable has passed the FT4 vertical-tray flame test
Giga or 1,000,000,000
Giga-Hertz
Hertz – 1 Hertz = 1 cycle per second
A symbol used to designate electrical curren (Amperes)
Kilo or 1,000
Kilo-Hertz
A symbol used to designate electrical inductance.
milli or .001
Mega or 1,000,000
Mega-Hertz
Nano or .000000001
Non-contaminating polyvinyl chloride
National Electrical Code – published by the NFPA
Nanofarad – one billionth of a farad.
National Fire Protection Association
Oxygen free copper –
Pico or .000000000001
Polyethylene
Picofarad – one trillionth of a farad.
Power Limited Tray Cable circuits – Article 760 of NEC
Polypropylene
Teflon
Polyurethane
Polyvinyl chloride
The military designation for coaxial type cables.
Silver coated copper
Tin coated copper
Thermoplastic elastomer
Thermoplastic rubber
Micro or .000001
Microfarad
– one millionth of a farad.
Underwriters Laboratories – an independent non-profit testing laboratory
Cross-linked polyethylene